TECHNICAL SPECIFICATIONS
General
• External cylinder diameter: 933mm
• Rated load: 205kg (two passengers)
• Speed: 0.15 m/s
• No pit required. The lowest-level floor must be completely level
as the lift rests on the existing floor
• No lift shaft required
• Minimum headroom:
o Standard head unit: 2700 mm
o Split unit: 2450 mm
• Aperture required for installation through floors and
ceilings: 990mm
Mechanical requirements
• 220 V, 60/50 Hz, 30amp single-phase power supply
• 5 turbine motors located in the pump, using a total of 5kW
Cabin
• Entrance opening width: 521 mm
• Internal cabin height: 2007mm
• Internal cabin diameter:
o Between columns: 750 mm
o Without columns: 820 mm
• Automatic LED lighting and cabin fan
• Door openings: same-side (in-line) and through-car (180o).
* 90o right or left. All upper floors must be on the same side as one
another.
o Viewed from inside the cabin, all doors are hinged at the top left and
open to the left
• Door height: 1970 mm
• Height to top of door closer: 2025 mm
o Each specified landing level includes only one door
• 24 Volt electrical circuits, with all controls in the cabin
• Push-button call controls with precise levelling at each landing
• Telephone
Safety
• Automatic descent to ground level at a safe speed in the
event of a power failure.
• Mechanical emergency brakes engage within 5cm of free fall in the
event of vacuum loss or catastrophic failure.
• Electromechanical interlocks at each landing.
• Alarm
• Warranty: 24-month limited warranty from installation
• Machinery Directive 2006/42/EC
• CE marking